Project
Sydney Water Corporation St Marys BioSolids Treatment Facility
Scope of Work
Design, manufacture, installation, commissioning and testing of an Odorgard® and Ammonia scrubbing system for the Bio-solids Treatment Facility.
Equipment Supplied
- FRP Scrubbers x 2 for H2S
- FRP Scrubbers x 2 for Ammonia
- Venturi Scrubber
- Odorgard® reactors
- Bulk chemical storage facility
- Chemical dosing pumps fans
- Recirculation pumps and piping
- Instrumentation
- Access platform
- Commissioning and performance testing
- Mechanical installation
- Operator training
Details
Location
St Marys, NSW
Project Duration
12 months
Completion Date
2001
Specifications
Ammonia Vent Rate
154,000m³/hr
Inlet H2S
25ppm
H2S Vent Rate
3700m³/hr
Inlet NH3
100ppm
Venturi Vent Rate
1800m³/hr
H2S outlet
50ppb
Ammonia Outlet
1ppm